Post Offer Free
Phenix Group Co.,Ltd.
Phenix Group Co.,Ltd.  

Gold Index: 43274

You are here: home  > Circuit breakers  > Vacuum Load Switches  > Indoor HV pressure-operated load switch

Indoor HV pressure-operated load switch 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: FN12-12D&FN12-12(R)D
Export Area: all over the world
Certificate: CE,ISO

indoor AC high voltage load switches,load switch,load switches

FN12-12D/630-20 type indoor AC high voltage load switches
FN12-12(R)D/125-31.5 type AC high voltage load switch- fuse combination units
FN12-12D/630-20 type indoor AC high voltage load switches is a rated voltage of 10KV, rated frequency 50Hz three-phase high-voltage switch equipment ,for the closing and opening load current, loop current, air containing transformers and cable charging current, short circuit current of the Closing. Equipped with grounding switch load switch that can withstand short-circuit current.
FN12-12 (R) D/125-31.5 type AC high voltage load switch- fuse combination units, is the FN12-12D load switch and S Δ LAJ-12 (XRNTΔ -10) high-voltage current-limiting type fuse combination units together in the indoor high voltage switchgear. It can be a reliable short-circuit breaking current up to any current; load switch breaking current, the fuse short-circuit breaking current breaking joint working between the current and total short-circuit current of any over-current, fuse through its impact to load switches opening.
Mainly technical parameters
No
Item
Unit
Value
1
Rated voltage
kV
10
2
Rated frequency
Hz
50
  3
Rated current
A
630
100
  4
Lightning impulse withstand voltage
kV
Earth and phase 75,  insulating fracture 85
  5
1min power frequency withstand voltage
kV
Earth and phase 42,  insulating fracture 48
  6
Rated thermal current
kA
20(4S)
  7
Rated dynamic current
kA
50
8
Rated closed current (peak)
kA
50
50
9
Rated short-circuit breaking current (predictive value)
kA
 
31.5
10
Max I2t on critical breaking current
A2S
 
Comply with fuse characteristic curve
11
Min breaking current
kA
 
Comply with fuse characteristic curve
12
Rated transfer current
kA
 
1.5
13
 Max breaking current (reference value)
kA
1.8
14
Breaking no-load transformer capacity
kVA
1250
15
 Rated cable charged current
A
10
16
Rated power load current breaking times
times
>100
17
Breaking times of striker with load-switch
S
 
>0.06
18
Earth switch thermal current
kA
20(2S)
19
Earth switch thermal current (peak)
kA
50
20
  Motor operate power voltage
V
AC DC current 110, 220
bigPhoto
 Mr. Tony

Tel: 86-577-27863960
Fax: 86-577-27863970
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Phenix Group Co.,Ltd. [China (Mainland)]


Business Type:Manufacturer, Trading Company
City: Wenzhou
Province/State: Zhejiang
Country/Region: China (Mainland)