Phenix Group Co.,Ltd.
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Max. output power | Input voltage | Output voltage | Output current range | Combined regulation |
3000W | 200-240Vac | +88.2+/-0.2Vdc | 30+/-1.0A | +/-0.2V |
No. | Item | Technical specification | Remark |
1 | Humidity | 5~95% | With package |
2 | Altitude | ≤3000m | Work normally |
3 | Cooling | The power supply is cooled | Working under full load |
No. | Item | Technical specification | Remark |
1 | Rated input voltage | 240Vac | |
2 | Input voltage range | 200~264Vac | |
3 | AC input voltage frequency | 47~63Hz |
No. | Item | Technical specification | Remark |
1 | Fast charge voltage | 88.2+/-0.2Vdc | |
2 | Floating voltage | 82.8Vdc | |
3 | Constant current | 30A | |
4 | Switch current | 6.0A | |
5 | Power efficiency | ≥90% | Vin=220Vac, rated load |
No. | Item | Technical specification | Remark |
1 | Over voltage protection | Lock out | |
2 | Software over voltage protection | The charger software limits the maximum output voltage to a level suitable for the connected battery system | |
3 | Thermal protection | An internal temperature monitor reduce charger output power in extreme operational temperature to prevent damage | |
4 | Current limiting protection | 30A | At CC mode |
5 | Short circuit protection | Short circuit protection should be automatically recovery after remove the condition | |
6 | Reverse polarity protection | When output wires are reversely connected to the battery the charger will not operate and will work normally when DC wires are correctly connected. | |
7 | Fan cooling | The fan is controlled by a temperature sensor. After charger works , the fan will run for 2min or so ( even several seconds); if the charger temperature is below 30~45 ℃, the fan will stop; if the charger temperature rise, the fan will run again; |
No. | Item | Status | Remark |
1 | Power on | LED1: red | |
2 | Charging | LED2: red | |
3 | Fully charged | LED2: green | |
4 | Completely charged | Charge current is very low(down to 0A) | Select switch at A position |
No. | Item | Standard ( or test condition) | Remark | |
1 | Electric strength test | Input-output | 1500Vac/10mA/1min | No breakdown |
2 | Isolation resistance | Input-ground | ≥10Mohm@500Vdc | |
Output-ground | ≥10Mohm@500Vdc | |||
3 | Leakage current | <3.5mA | Vin=264Vac | |
4 | Safety | CE / UL compliant | ||
5 | EMC | EN55022:1998+A1:2000+A2:2003 EN55024:1998+A1:2001+A2:2003 (EN61000-4-2:1995+A1:1998+A2:2001 EN61000-4-3:2002 EN6100-4-4:1995+A1:2000+A2:2001 EN61000-4-5:1995+A1:2000 EN61000-4-6:2001 EN61000-4-11:2001) | ||
6 | LVD | EN60335-1:2002+EN60335-2-29:2002 |
No. | Item | Technical specification | Remark |
1 | High temperature ambient operating | +40℃ | Features ok |
2 | Low temperature ambient operating | -10℃ | Features ok |
3 | High temperature storage | +70℃ | Work normally after recovery under normal temperature for 2hours |
4 | Low temperature storage | -40℃ | Work normally after recovery under normal temperature for 2hours |
5 | Random vibration | 20Hz to 2000Hz 3Grms 20hours per axis | |
6 | Repetitive shock | 40g peak 3 orthogonal axes, 3+ and 3- in each axis, 11ms pulse width | |
7 | Thermal shock | -35℃ to 75℃, <3min transition, 2.5hours dwell, 200cycle | |
8 | Drop test | BS EN60068-2-32:1993 TEST ED: free fall appendix B |